Application :
These types of cables are suitable for welding with electric arc, for this type of cables which are intended exclusively for welding purposes, the nominal voltage has not been determined.
The insulation of this type of cable can withstand temperatures of 90 to 150 degrees Celsius. Welding cables must have high flexibility and high strength due to its bending and moving.



Cable structure:
Coating:TPR

 
Standard: 245 IEC 81 ISIRI (1926) 81

 
Approximate weight
Maximum conductor resistance

 
Coating thickness

 
Average outer diameter (upper limit)

 
Average outer diameter (lower limit)

 
Maximum conductor diameter

 
Cable cross section

 
Kg/km Ω/km mm mm² mm² mm² mm²
218 1.16 2.4 11 8.8 0.21 16
304 0.758 2.4 12.7 10.1 0.21 25
403 0.536 2.4 14.2 11.4 0.21 35
560 0.379 2.7 16.5 13.2 0.21 50
772 0.268 3 19.2 15.3 0.21 70
1016 0.198 3.2 21.4 17.1 0.21 95
Your rating to this product